Pneumatic Filter Regulator Lubricator - check bulb, fittings, gauge, and knob
Common Component Failure Problems
- Fittings/connections are not secure and are leaking
- Check connections (possible leak points) for leaking
- Gauge is not working properly
- Indicator does not move when there is a change in pressure flow (when the pressure is increased or decreased)
- Adjustment knob is damaged or broken
- Knob won't turn one way or the other
- Fittings are not hooked up properly
- Can sometimes happen after having been replaced
- Air flow is hooked up in the wrong direction
- Check the incoming air direction to make sure it is going the same direction as the arrow on the PFRL
- Collection bulb is damaged or leaking